Squirrel Input Type : D

· For State or Event measurement

D Inputs can be used to record the state of eight event lines, or record a single 8 bit number.

State

  • The eight input lines are treated as 8 bits of a binary number, so as to provide a number between 0 and 255.
  • The input can be configured to accept a voltage free contact or voltage signal.
  • Recordings can be set to be period or event driven.
  • Typical applications might include monitoring of a water level using a grey scale depth encoder.

State/Event

  • Up to eight input lines are recorded as a 1 or 0.
  • Recordings can be set to be period or event driven.
  • Each input can be configured to accept a voltage free contact or voltage signal. (<1v = low, >4v = high)
  • Typical applications might include monitoring activation of door contacts within a building.

Ranges available in the Squirrel data logger:

Min Max Application
0 255 State
00000000 11111111 State / Event

Squirrel modules available:

Module D inputs Other inputs
CPU 1 x 8 1 Pulse
M09A 3 x 8 -
M09B 8 x 8 -

 