Transmitters for monitoring digital state

20 and 30 Series

GS24 and GD24

4 state inputs (or K/T thermocouples -200 to +200°C), e.g. door open/close.

GS34/GS38 and GD34/GD38

4 / 8 state inputs (or thermistor), e.g. door open/close.

GS24

GS24

60 Series

GC60

2 state inputs, e.g. door open/close.

GC60Z

2 state inputs, e.g. door open/close, with additional functionality designed for a system monitoring changes of events in real time.

GC60Y

2 count inputs to monitor the opening and closing of one or two contacts (e.g. a door or window magnet activated contact).
4 x calculated channels providing additional data about the relationship between the states of the two doors/windows.

GC60

GC60

Sensors

If you require sensors, please order them separately.

Accessories

WBG Wall bracket docking kit

This kit enables fitment of the transmitter's built-in wall bracket to difficult or uneven surfaces. The kit provides additional docking security.

The following products are supported:

  • All GD, GC, GL and GS series transmitters
  • RP250GD repeater and RC250 receiver

WBG

Common GenII Transmitter Specification

RF specification: EN300-220
RF power: 10mW
Environment specification  
  Compliant to EN300-220: -10 to +55°C
  Actual: -30 to +65°C
  Humidity: 100% non condensing
Environmental rating: IP40
Dimensions (footprint): 78 x 41mm
Transmission interval range: 1 sec to 4 hours
Indicator (red LED): transmit active/on/off
Control switch (concealed): test mode / hibernate
Antenna socket: SMA

Transmitter Specification

Model(s) Sensors Range Resolution Accuracy
GS24/GD24 4 x external T or K type thermocouple temperature / state inputs -200 to 200°C 0.1°C / 0.2°C ±0.3°C
GS34/GD34
GS38/GD38
4 x external thermistor temperature / state inputs
8 x external thermistor temperature / state inputs
-50 to 150°C 0.05°C (-5 to +75°C)
0.1°C (-25 to +100°C)
0.2°C (-40 to +125°C)
±0.1°C (-5 to +75°C)
±0.2°C (-25 to +100°C)
±0.4°C (-40 to +125°C)
GC60 2 x state indications
GC60Y 2 x physical inputs indicating the number of open and close events of the door contact.
2 x one second counters to provide the accumulative total of how long the door contacts on the physical inputs were open.
1 x count (accumulated) of the number of times both doors are open together.
1 x one second counter for previous channel showing accumulative total of how long both doors were open together (shown in seconds).