4 state inputs (or K/T thermocouples -200 to +200°C), e.g. door open/close.
4 / 8 state inputs (or thermistor), e.g. door open/close.
GS24
2 state inputs, e.g. door open/close.
2 state inputs, e.g. door open/close, with additional functionality designed for a system monitoring changes of events in real time.
2 count inputs to monitor the opening and closing of one or two contacts (e.g. a door or window magnet activated contact).
4 x calculated channels providing additional data about the relationship between the states of the two doors/windows.
GC60
If you require sensors, please order them separately.
This kit enables fitment of the transmitter's built-in wall bracket to difficult or uneven surfaces. The kit provides additional docking security.
The following products are supported:
WBG
RF specification: | EN300-220 | |
RF power: | 10mW | |
Environment specification | ||
Compliant to EN300-220: | -10 to +55°C | |
Actual: | -30 to +65°C | |
Humidity: | 100% non condensing | |
Environmental rating: | IP40 | |
Dimensions (footprint): | 78 x 41mm | |
Transmission interval range: | 1 sec to 4 hours | |
Indicator (red LED): | transmit active/on/off | |
Control switch (concealed): | test mode / hibernate | |
Antenna socket: | SMA |
Model(s) | Sensors | Range | Resolution | Accuracy |
GS24/GD24 | 4 x external T or K type thermocouple temperature / state inputs | -200 to 200°C | 0.1°C / 0.2°C | ±0.3°C |
GS34/GD34
GS38/GD38 |
4 x external thermistor temperature / state inputs 8 x external thermistor temperature / state inputs |
-50 to 150°C | 0.05°C (-5 to +75°C) 0.1°C (-25 to +100°C) 0.2°C (-40 to +125°C) |
±0.1°C (-5 to +75°C) ±0.2°C (-25 to +100°C) ±0.4°C (-40 to +125°C) |
GC60 | 2 x state indications | |||
GC60Y | 2 x physical inputs indicating the number of open and close events of the door contact. 2 x one second counters to provide the accumulative total of how long the door contacts on the physical inputs were open. 1 x count (accumulated) of the number of times both doors are open together. 1 x one second counter for previous channel showing accumulative total of how long both doors were open together (shown in seconds). |
Gen II Quick Start Instructions
ELCC (a sensor for detecting the failure of AC mains supply)